SM6000 SERIES DC Power Supply

SM6000 SERIES DC Power Supply

Output power: 6000 W.

Laboratory DC power supply.

Programmable, regulated PSU.

Bench or 19″ rack mounting.

Units:

Unit Voltage range Current range
SM 15-400 0 – 15 V 0 – 400 A
SM 30-200 0 – 30 V 0 – 200 A
SM 45-140 0 – 45 V 0 – 140 A
SM 60-100 0 – 60 V 0 – 100 A
SM 70-90 0 – 70 V 0 – 90 A
SM 120-50 0 – 120 V 0 – 50 A
SM 300-20 0 – 300 V 0 – 20 A
SM 600-10 0 – 600 V 0 – 10 A

Features:

  • Designed for long life at full power
  • Excellent dynamic response to load changes
  • Protected against all overload and short circuit conditions
  • EMC surpasses CE requirements: low emission und high immunity
  • Low audible noise: fans are temperature controlled

Functionalities:

  • Master / Slave parallel and series operation with voltage and current sharing
  • Stacking is allowed, space between units is not required
  • High power system configuration from multiple units
  • 19” rack mounting or laboratory use (feet included)
  • Remote sensing
  • Interlock

Specifications:

Input voltage (3 phase, 342 – 528 V AC,
rated voltage range) Vnom line to line (48-62 Hz)
Active Power Factor Correction (PFC) 0.98 (at 100% load)
Efficiency up to 90% (at full load)
Output ripple and spikes from 0.8 mVrms / 10 mVpp
Regulation from 2.5 mV (0-100% load step)
Recovery time from 100 μs (50-100% load step)
Programming speed from 2.7 ms (10-90%),optional from 0.4 ms
Analog programming accuracy from 0.2%
Output voltage and current stability 5.10-5 / 10.10-5
MTBF 500.000 hrs
Operating ambient temperature -20 to +50 °C

Standards:

  • Power supply standard : EN 61204-3
  • Generic Emission : EN 61000-6-3 (EN 55022B)
  • Generic Immunity : EN 61000-6-2
  • Safety : EN 60950 / EN 61010
  • Insulation input / output : 3750 Vrms
  • Protection class : IP20
  • cTÜVus

Dimensions and weight:

  • Width = 19
  • Height = 4 U
  • Depth = 542 mm
  • Weight = 27 kg